XH-W1301 Digital Temperature Thermostat Controller Switch Cooling Heating DC 12V 24V

FOB Reference Price:Get Latest Price
$2.50 - $3.00 / Piece | 20 Piece/Pieces (Min. Order)
Shipping:
Support Sea freight
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
GEREE
Model Number:
W1301
Usage:
Industrial
Theory:
Temperature Sensor
Accuracy:
0.1 ℃
Temperature range:
-50°C ~ 110°C
Measuring accuracy:
±0.2 °C
Power supply:
DC 12V 24V Adjustable
Output capacity:
Max 10A
Control precision:
±0.1 °C
Measuring input:
1 m waterproof probe
Input voltage:
12V 24V acceptable
Size:
78*51mm
Name:
Thermostat
Supply Ability
Supply Ability:
10000 Piece/Pieces per Week
Packaging & Delivery
Packaging Details
polybay,can make the package according to customers' requirements
Port
shenzhen/HongKong
Lead Time :
within 5 days after payment

XH-W1301 Digital Temperature Thermostat Controller Switch Cooling Heating DC 12V 24V


1.product features
1, patch technology higher performance, lower power consumption!
2, the positive and negative components are designed to fit into the panel installation
3, high speed flash memory RAM processing chip
4, power setting automatic memory
0.1, control accuracy of 5 degrees Celsius
6, button buzzer (can be closed)
7, high temperature buzzer alarm (0-110 degree of freedom)
8, back to the difference between the 0.5 settings, can control the decimal (0.5-15.0)

2.technical parameters
Temperature control range: -50~110
Resolution: -9.9~99.9 at 0.1 C and other temperature 1
Temperature measurement accuracy: 0.1
Control precision: 0.1
Return precision: 0.1
Refresh rate: 0.5 S
Input power: 12V DC/AC
Measurement input: NTC (10K 0.5%) waterproof type sensor
Output: 1 way relay output, capacity =10A
Environmental requirements: -10~60 C humidity 20%-85%
Specification: 78*51mm (mounting hole M3. diagonal 75mm)
Power consumption: static current: 35MA operating current: less than 65MA

methods
Connect the power supply and equipment, can supply the controller, the display for measuring temperature, press the SET button once, the temperature display flashes, according to set the desired temperature (+ - + - hold fast lifting) after the completion of the set by SET to confirm the return, the controller according to the set automatic relay on-off! The output of the temperature controller is a 10A relay, which can satisfy all kinds of high power load and connect the control circuit, which can supply power for the temperature controller,


Four, indicating lamp, digital tube and buzzer state
Indicator: flashing indicates cooling or heating start delay, and the relay has been closed.
Digital tube: LL display for the sensor open, please follow the instructions connected to the sensor; display HH to exceed the measuring range of the thermostat will be forced to disconnect the relay; display --- for the high temperature alarm
Buzzer: digital tube display LL, HH or --- when the buzzer issued di - di - di - di - tone

Five, parameter function description
Long press SET 5 seconds into the main menu set, according to the P0 P8 + - switch... Press SET or 10 seconds without key action controller automatically confirm return


P0 refrigeration and heating mode

Long press 5 seconds to show SET P0, set the operating mode according to a SET, by
switching H for heating mode + - [] [C] for the cooling mode by a SET return, press SET or 10 seconds without key action controller automatically confirm completion Cooling mode: when the temperature measurement value is more than the temperature set point, refrigeration relay, refrigerator start; when the temperature measurement value is less than or equal to the temperature set point - return difference, refrigeration relay off, close the refrigerator


Heating mode: when the temperature measurement value is less than or equal to the set point temperature, heating relay, heater start; when the temperature measurement value is more than the set point temperature difference +, heating relay disconnect heater off.


P1 return difference setting
Long press 5 seconds to show SET P0, press the + - switch to P1 SET by a set back value, according to the difference of 0.5-15 + - set back, after the completion of a return to the SET, press SET or 10 seconds without key action controller automatically confirm completion Cooling mode: when the temperature measurement value is more than the set value, relay,
refrigerator start; when the temperature measurement value is less than or equal to the set value - difference when the relay is switched off, close the refrigerator.

 

For example, the environment of 30 degrees set value of 25 degrees, the return difference set as 2 DEG C, after power relay is closed when the refrigerator starts cooling to 23 DEG C, relay off refrigerator closed at this time due to cooler has been disconnected when the temperature began to rise, rise to the set value of 25 degrees, the relay is closed refrigerator starts again, this repeated cycle control temperature is not higher than 25 DEG C


Heating mode: when the temperature measurement value is less than or equal to the set value, relay, heater start; when the temperature measurement value is more than the set value + hysteresis, relay off, heater off.
For example, the environment of 10 degrees set value of 25 degrees, the return difference set as 2 DEG C, after power relay is closed heater start, when heated to 27 DEG C, the relay disconnect the heater off, at this time because the heater has been disconnected when the temperature began to fall down to set the value at 25 DEG, the heater relay is closed again, this repeated cycle control temperature not lower than 25 DEG C


P2 maximum temperature setting limit:
In order to avoid the mistake caused by the wrong operation, the setting temperature is too high, the temperature controller has the highest setting function, which limits the maximum temperature setting range of the temperature controller.
Long press 5 seconds to show SET P0, press the + - switch to P2 SET by a set limit, setting the highest temperature can be set by + -, the maximum value is 110, after the completion of a return to the SET, press SET or 10 seconds without key action controller automatically confirm completion


For example: set to 60 temperature set point can only be set to 60 C if the temperature set point higher temperature range to expand, need to adjust the upper limit of the set value.


P3 low temperature setting lower limit:
In order to avoid wrong operation caused by the temperature is too low, the temperature controller has the lowest set upper and lower limits, limiting the temperature controller to control the set range of the minimum temperature setting point Long press 5 seconds to show SET P0, press the + - switch to P3 SET by a set minimum limit, set the minimum temperature can be set according to the minimum value of -50 + - and, after the completion of a return to the SET, press SET or 10 seconds without key action controller automatically confirm completion


For example: set to 2 temperature set point can only be set to 2 C if the temperature set point lower temperature range to expand, you need to adjust the lower limit of the set value.


P4 temperature correction
This function can be used when measuring the temperature and the standard deviation of the temperature or because of the special needs of the user's hardware, this function can be used to correct the temperature after correction.


Long press 5 seconds to show SET P0, press the + - switch to P4 SET by a corrected set correction value by + - according to a return, after the completion of SET, long press SET or 10 seconds without key action controller automatically confirm completion
For example, the normal display is 25 degrees; the temperature correction is 0 when the display 25 degree; the temperature correction is 1.5 when the display 26.5 degree; the temperature correction is -1.5 when the display 23.5;


P5 delay start time unit: Min
When the refrigerator or heater delay when needed, can open the delay function, protect the life of the equipment
Long press 5 seconds to show SET P0, press the + - switch to P5, set start delay time unit is minute by one SET, by setting the 0-10 + - points, after the completion of a return to the SET, press SET or 10 seconds without key action controller automatically confirm completion


Cooling mode: first energized, if the current temperature is greater than or equal to the set value, the refrigerator will not immediately start refrigeration, need to set delay time after the start of operation


Heating mode: first energized, if the temperature is less than or equal to the set value, the heater will not immediately start heating, need to set delay time after the start of operation


Between two adjacent or cooler heater start stop time is greater than the start delay time setting value, immediately start the refrigerator;Between the cooler or heater adjacent two start stop after a lapse of less than the start delay time setting value, start again to be run by the end of the refrigerator set start delay time, the equipment can be started. Delay time from the start to calculate the moment.


For example, under the condition of refrigeration set delay of 5 minutes, the refrigerator start delay after startup, 5 minutes after the opening when the refrigerator reaches the required temperature when the refrigerator stops, then start the timer, the next time the refrigerator start timing immediately when the unfinished work completed, to the end of time time to work, time delay in LED flashing lightsDelay start set to 0 is equal to the closing delay function


P6 push button switch
Long press 5 seconds to show SET P0, press the + - switch to P6 SET by a set whether to open the key sound, set the on/off + - according to the completion of return, according to a SET, press SET or 10 seconds without key action controller automatically confirm completion
Buzzer switch on/off set to on when the button with the button to send a drop sound, set to off, that is, the closure of the buzzer, no sound button


P7 high temperature alarm
Long press 5 seconds to show SET P0, press the + - switch to P7 on/off by a SET (off to close the secondary function) is set to on SET by a high temperature alarm can be set according to the set temperature point, + - 0~110, after the completion of a return to the SET, press SET or 10 second no button action controller automatically confirm completioHigh temperature alarm set range of 0-110 or off to close the function, to reach the high temperature alarm buzzer issued by the sound, while the forced open relay


For example, we want to give a liquid or space heating to 40 degrees, 80 degrees for the dangerous set temperature, the working process due to irresistible external factors lead to dangerous temperature when the temperature is above 80 degrees, the temperature started to disconnect the buzzer alarm relay rapid alarm, a timely reminder of the staff to take corresponding measures to restore the loss! Alarm temperature can be set according to the actual needs, if you do not want this feature can be set to off temperature, pay attention to, when the normal temperature to restore the normal temperature alarm


P8 restore factory settings
As a result of some man-made temperature controller internal chaos, one to set a very time-consuming, this function can be used to restore the factory settings, the specific method for theLong press 5 seconds to show SET P0, press the + - switch to P8, according to a SET set to on or off, on to restore the factory settings, off does not perform any action, after the
completion of a return to the SET, press SET or 10 seconds without key action controller .


automatically restore factory settings parameters in