Geree DC 5V 12V 24V delay on/off Cycle timer self locking latching Multifunction trigger relay module

FOB Reference Price:Get Latest Price
$3.50 - $4.00 / Piece | 10 Piece/Pieces (Min. Order)
Shipping:
Support Sea freight
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
GEREE
Model Number:
R04MC
Size:
Miniature
Usage:
PCB
Theory:
Voltage Relay
Protect Feature:
Sealed
Contact Load:
Low Power
voltage:
5V 12V 24V
size:
63.5*38.5*18.5mm
Install dimension:
58.5*33.5mm
load:
AC 220V or DC 30V 10A
Supply Ability
Supply Ability:
1000 Piece/Pieces per Week
Packaging & Delivery
Packaging Details
ordinary gift box can make the package according to customers' requirements
Port
shenzhen/HongKong
Lead Time :
Shipped in 5 days after payment

Geree DC 5V 12V 24V delay on/off Cycle timer self locking latching Multifunction trigger relay module

 

I. Introduction:
size 63.5*38.5*18.5mm
Install dimension:58.5*33.5mm
load:AC 220V or DC 30V 10A
1.jpg2.jpg
This product sets the power trigger delay, cycle timing delay, high and low pulse trigger delay and self-locking, point trigger in one, with digital timer relay module, with a delay accurate, 18 kinds of optional, the largest Can be connected to 220V 10A AC or 30A 10A DC load, widely used in smart home, automation control, product life testing, electronic enthusiasts design applications. Products are 5V, 12V, 24V three voltage versions optional, the delay time are 1-999 seconds and 1-999 minutes to choose, according to the need to select the appropriate voltage version.
Second, the function introduced:
This product has 18 kinds of function selection, the specific function is as follows:
Power-on (power-up) delay function section:

Function 1 (timer disconnection): The relay is switched on at power-up, and the relay is disconnected after the delay time has expired (with power remaining). The time is between 1 second and 999 seconds (or 1-999 minutes) Such as re-power or to the IN interface a trigger signal (support high / low trigger, external switch button trigger), can be interrupted and repeat the above function;

Function 2 (timer pull-in): the relay is disconnected at power-up, and the relay pulls up when the delay time is over (there is always the hold), and the time is between 1 second and 999 seconds (or 1-999 minutes) Such as re-power or to the IN interface a trigger signal (support high / low trigger, external switch button trigger), can be interrupted and repeat the above function;

Function 3 (Timing pull-in and then disengage): When the relay is energized at power-up, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is off (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). The relay will remain on until the end of the disconnection, such as re-energizing or a trigger signal to the IN connector (Support high / low trigger, external switch button trigger), can be interrupted and repeat the above function;

Function 4 (timer disconnect and then pull): The relay is disconnected at power-up, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). The relay will remain off after the end of the suction delay, such as re-energizing or giving a trigger signal to the IN interface (Support high / low trigger, external switch button trigger), can be interrupted and repeat the above function;
Cyclic timing function section:

Function 5 (infinite cycle timing mode 1): After the power relay, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is disconnected after the suction delay , The turn-off time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay presses the T1 time again after the break-up delay. Such as re-power or to the IN interface, a trigger signal (support high / low trigger, external switch button trigger), can be interrupted and repeat more than one function;

Function 6 (infinite cycle timing mode 2): The relay is disconnected after power-up, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay pulls off after the break , The pull-in time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is turned off by the T1 time again after the suction delay is completed. Such as re-power or to the IN interface, a trigger signal (support high / low trigger, external switch button trigger), can be interrupted and repeat more than one function;

Function 7 (limited cycle timing mode 1): After the power relay, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is disconnected after the suction delay is completed , The off time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the end of the break, the relay will press the T1 time again. The number of cycles can be set in 1-999 times. Such as re-power or to the IN interface, a trigger signal (support high / low trigger, external switch button trigger), can be interrupted and repeat more than one function;
Function 8 (limited cycle timing mode 2): The relay is disconnected after power-up, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay pulls off after the break (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the end of the suction delay, the relay is switched off at T1 time again, and the number of cycles can be set in 1-999 times. Such as re-power or to the IN interface, a trigger signal (support high / low trigger, external switch button trigger), can be interrupted and repeat more than one function;
Trigger delay function section:

Function 9 (trigger timing off 1): After power-up, the relay does not operate to be disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when the trigger signal, the relay suction The pull-in time is adjustable between 1 second and 999 seconds (or 1-999 minutes), the delay is over, the relay is disconnected, waiting for the next trigger signal, and the IN interface trigger in the delay is invalid.

Function 10 (trigger timing pull 1): After power-up, the relay does not act to be disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when there is a trigger signal, the relay to maintain Off and the delay time between 1 second and 999 seconds (or 1-999 minutes) between the adjustable, the delay is over, the relay pull (with electricity will always keep the pull), waiting for the next trigger signal , The IN interface triggering in the delay is invalid.

Function 11 (Trigger Timing Disconnect 2): After power-up, the relay does not operate to be disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when there is a trigger signal, the relay suction The pull-in time is adjustable between 1 second and 999 seconds (or 1-999 minutes), the delay is over, the relay is disconnected, waiting for the next trigger signal, and the IN interface trigger is active in the delay.

Function 12 (trigger timing pull-up 2): After power-up, the relay does not operate to be
disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when there is a trigger signal, the relay to maintain Off and the delay time between 1 second and 999 seconds (or 1-999 minutes) between the adjustable, the delay is over, the relay pull (with electricity will always keep the pull), waiting for the next trigger signal , The IN interface trigger in the delay is valid.

Function 13 (trigger timing disconnect and then pull 1): After power on, the relay does not act to be disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when there is a trigger signal (T1) in 1 second -999 seconds (or 1-999 minutes) between the adjustable, after the end of the delay relay pull, pull the time (T2), the relay is turned off and the delay time, ) Is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay will remain open until the suction delay is completed. Waiting for the next trigger signal, the delay in the IN interface trigger is invalid.

Function 14 (trigger timing pull and then off 1): After power on, the relay does not operate was disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when there is a trigger signal (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay is turned off after the end of the suction delay, and the off time (T2) is in the range of 1 Sec -999 seconds (or 1-999 minutes) between the adjustable, disconnect the delay after the relay will remain in touch. Waiting for the next trigger signal, the delay in the IN interface trigger is invalid.

Function 15 (trigger timing disconnect and then pull 2): ??After power on, the relay does not act to be disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when a trigger signal (T1) in 1 second -999 seconds (or 1-999 minutes) between the adjustable, after the end of the delay relay pull, pull the time (T2), the relay is turned off and the delay time, ) Is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay will remain open until the suction delay is completed. Waiting for the next trigger signal, the delay in the IN interface trigger is valid.

Function 16 (trigger timing and then disconnect 2): After power-up, the relay does not act to be disconnected, waiting for the IN interface trigger signal (support high / low trigger, external switch button trigger), when there is a trigger signal (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay is turned off after the end of the suction delay, and the off time (T2) is in the range of 1 Sec -999 seconds (or 1-999 minutes) between the adjustable, disconnect the delay after the relay will remain in touch. Waiting for the next trigger signal, the delay in the IN interface trigger is valid.

Function 17 (self-locking relay function): When the IN interface has a trigger signal (support high / low trigger, external switch button trigger), relay pull, give a signal, the relay disconnect, press the 8 Sel key Simulation test function.

Function 18: (trigger relay function): When the IN interface has a trigger signal (support high / low trigger, external switch button trigger), the relay pull, the signal disappears, the relay is disconnected.

realy module